Call Us Now! 6 012 2151684
For product enquiry or problem? Email us at info@smhealthcare.com.my

PRODUCTS

PCA/PCEA PUMP - SPACE

S-A-8713030

Specification:

B.Braun Perfusor Space PCA/PCEA innovative drive technology not only ensures excellent startup and delivery properties, but also delivers safety and unique convenience when changing syringe

 

Feature:

  1. Comfortable PCA button with fixation clip and patient wristband.
  2. Dedicated key locks the syringe holder.
  3. Access code-protected settings.
  4. Integrated piston brake prevents free-flow during syringe change.
  5. Automatic rate calculation by calculating volume over time.
  6. Automatic calculation of delivery rate in ml/h based on the entry of drug concentration in conjunction with the desired dose rate (eg: ml/kg/min).
  7. Changing of infusion rate without delivery interruption
  8. Last memory retrieved, infusion will restart with continuation from the last infusion rate.
  9. Drug Library : up to 720 drug names including therapy data and information can be stored in 15 categories
  10. Drug specific soft and hard limits as well as default values can be specified
  11. KVO mode: the pump can continue the infusion with a preset Keep Vein Open after a pre-selected VTBI / time has passed.
  12. Standby time adjustable from 1 minutes up to 24 hours.
  13. Automatic detection of syringe sizes 2/3 ml, 5 ml, 10 ml, 20 ml, 30 ml, 50/60 ml, selectable by menu.
  14. Automatic bolus reduction triggered by occlusion alarm.
  15. Keypad lock on 2 safety levels (parameters and disposables lockable).
  16. LED Alarm indicator with clear alarm message in display.
  17. Drug specific acoustic alarm priorities can be specified.
  18. 9 selectable occlusion pressure levels (approx 0.1 - 1.2 bar).
  19. Stackable modules with or without special docking station allow easy transport

Technical details:

1. Delivery range

  • 0.01-999.9 ml/h
  • 0.01-99.99 ml/h in 0.01 ml/h increments
  • 100.0 - 999.9 ml/h in 0.1 ml/h increments

2. Volume pre-selection

  • 0.1-9999 ml
  • 0.1 -99.99 ml in 0.01 ml increments
  • 100.0 - 999.0 ml in 0.1 ml increments
  • 1000 - 9999 ml in 1 ml increments

3. PCA Profile

  • Monitoring timeframe: 1 - 24 hrs
  • Dose volume limit for monitoring interval: 0.1 - 99999 ml
  • Limit on number of doses for monitoring interval: 0.001 - 99999 dose
  • Initial bolus: 0/0.1 - 200/1200 ml/h, 0 - 99999 dose (can be disabled)
  •  Basal rate: 0/0.1 - 200/1200 ml/h, 0/0.001 - 99999 dose (can be disabled)
  • Lockout time: 1 - 240 min
  • PCA bolus amount 0 - 99.99 ml, 0 - 99999 dose
  • Bolus rate: 0 - 1800 ml/h
  • Standards: Start up pre-settings can be defined for all parameters
  • Overdosage prevention: Warning and max. limits can be defined for all parameters
  • Country of origin: germany
Brand: B.BRAUN