PERFUSOR COMPACT PLUS - INFUSSION SYRINGE PUMP
S-A-8717030
Description:
The perfusor compactplus is an infusion syringe pump, which in combination with specific disposbales and accessories intended for a variety of medical infusion therapies , patient population, operator, environment and data exhange applications.
1. Dimension : 290 x 98 x 220 mm (W x H x D)
2. Weight: 2.3 kg (including integrated compactplus handle and pole clamp)
3. Operator interface
- Color active matrix 2.4" TFT, 240 x 320 pixels, 262k colors, viewing angle: all
80°.
- Visibility from all angles
- Color coded drug library.
- Intuitive user interface due to self explanatory, guiding pictures menu.
- Clear display of flow rate, flow volume, alarm status and battery status.
- Night mode with reduced display brightness is possible either by manual adjustment or automatic according to time schedule.
4. Language : English/B.Malaysia/ other language
5. Fluid Protection and Robust Design (P34 Rating) :
- Protected against solid objects over 2.5 mm.
- Protected against water splashed from all directions
6. Power supply :
- Integrated power supply for use with standard power cords ,
- 100-240 V AC, 50-60 Hz, connection via power cable or Station compactplus.
7. Syringe Size
- Automatic detection of syringe sizes 2/3 ml, 5 ml, 10 ml, 20 ml, 30 ml, 50 /60 ml,
selectable by menu. Compatible with major syringe brand such as B. Braun, Terumo,
B-D, Monoject.
8. Internal battery (Lithium-ion battery)
- Battery life approx. 10 h at 25 ml/h with 50 ml syringe.
- Recharging time approx. 3 h.
- Automatic battery charging during connection to mains.
- Switchover from mains to battery operation without data loss or loss of input.
9. Interfaces
- Cold connector for mains voltage.
- Accessory port for interface cable 12 V CP and staff call (VDE 0834).
- Infrared for communication in the station and for service
10. Operating conditions
- Temperature : +5 °C … +40 °C
- Relative humidity : 30% … 90% (without condensation)
- Atmospheric pressure : 0.54 … 1.06 bar
11. Storage conditions
- Temperature : -20 °C … +55 °C
- Relative humidity : 20 % … 90% (without condensation)
- Atmospheric pressure : 0.5 … 1.06 bar
12. Product Classification
- According to EN 60601-1:
-Protection class II
-For Type CF applied parts with defibrillation protection
-Land and air ambulance certified
Specification:
1. Flow rate range : - 999.9 ml/h , - 999.9 ml/h
2. Flow parameters :
- Calculation of the rate by selecting the time & volume
- Rate change without flow interruption
- The up, down, right & left buttons can all be used to set the decimal places as
well as the units, tens, hundreds etc. numbers of different values (e.g. flow
rate).
3. Dosage Calculation
- Automatic calculation of the flow rate on the basis of dosage units in mg, µg,
ng, IU, mmol or mEq.
- Calculation using time-based or optionally, weight-based (e.g. mg/kg/min;
mg/kg/h; mg/kg/24h).
- Surface-related calculation (DuBois).
4. Bolus rate : 1-1800 ml/h set in Steps of 0.01 ml/h.
5. Possibilities of Bolus
- Bolus volume by bolus during the flow is pre-selectable (0.1ml – 50ml or max.
syringe volume in ml).
- Bolus without volume pre-selection by the pressing of a button.
- Automatic calculation of bolus rate after the input of the bolus volume-and
time.
- Bolus in mg, µg, IE, mmol, mEq and optionally weight-based (Dosage Unit/kg),
as well as in ml; additionally automatic calculation of bolus rate after bolus
infusion.
- Automatic reduction of the syringe specific bolus volume after a pressure alarm
at system closure (max. <0.2ml)
6. Volume preselection : 0.01 ml - 999.9 ml in increments of 0.01 ml.
7. Time preselection: 0h 01min – 99h 59min
8. Alarm Signals : Pre-alarms for volume nearly infused, syringe nearly empty, infusion time
nearly reached, battery nearly empty, KVO time nearly reached.
9. Dose Error Reduction Systems (DERS)
- Drug library,More than 3,000 drugs, Specific care units & 30 categories
10. KVO Rate
- Rate: ≥ 10 ml/h: KVO rate 3 ml/h
- Rate: < 10 ml/h: KVO rate 1 ml/h
- Rate: < 1 ml/h: KVO rate = rate set using the service program (factory default rate 0.1
ml/h) or current rate if this is lower.
11. Warranty: 2 years from date of commissioning
12. MDA Registration : GC58781844118
Brand: B.BRAUN