BENEFUSION SP3 SYRINGE PUMP
S-A-L06-SP3
DESCRIPTION
Friendliness
- One hand operation and intuitive keypad
- Compact and lightweight design for easy carrying
- Long runtime battery, suitable for emergency and patient transfer
Safety
- High accuracy; ±2% satisfying neonatal use
- Fast start function against start delay due to friction
- Dynamic pressure detection, Anti-bolus, Last parameter configuration, Drug library, History Events
- IP24 water and dust protection, support cleaning with water
Connectivity
- Ambulance support
- Wifi connection available
- Dock support
Specifications and Functions
- Dimension - 330 x 126 x 110mm
- Syringe Size - 5, 10, 20, 30, 50/60 ml
- Infusion mode - Rate mode, Time mode, Body weight Mode
- Flow rate range - 5ml syringe: (0.1~150) ml/h; 10ml syringe: (0.1~300) ml/h; 20ml syringe: (0.1~600) ml/h 30ml syringe: (0.1~900) ml/h; 50ml/60ml syringe: (0.1~1500) ml/h
- Accumulated volume : 0.1~9999 ml, increment is 0.1 ml
- VTBI - 0.1~9999 ml, increment is 0.1 ml
- Increment - 0.1~9999 ml, increment is 0.1 ml/h; 1000~1500 ml/h, increment is 1 ml/h
- Accuracy - Flow rate ≥1 ml/h: Accuracy ≤ ±2%; Flow rate < 1 ml/h: Accuracy ≤ ±3%
- KVO rate - 0.5ml/h, adjustable
- Bolus/Purge rate - 0.10-1500ml/h (depending on syringe size)
- Occlusion - Low 300±75 mmHg (40kPa) Medium 525±75 mmHg (70kPa); High 900±135 mmHg (120 kPa)
- Screen - 3.0" LCD monochrome screen, 240 x 128 Pixels
- Titration - Yes
- Keypad lock - Yes
- Pause - Yes
- Automatic recognition of syringe size - Yes
- Self-test system - Yes
- Last parameter configuration - Yes
- Drug library - 200 drugs
- History record - 1500 events
- Weight: <1.8kg (including clamp)
- Dock - supported
- Handle - Included
- Mouting type - Standard: Vertical Pole; Optional: Horizontal Pole
- Alarm volume : 1-8 levels, selectabled
- Preset Syringe brand - 8, include B-D, B.Braun, Terumo, and 5 chinese brand; local brand configuration supported
- Language - 11, chinese, English, French, Russian, Turkish, Portuguese, Polish, Bulgarian, Czech, Romanian
Alarm
- VTBI done, VTBI near done, KVO finish, syringe empty, syringe near empty, syringe disengaged, occlusion, system error, system abnormal, battery low, battery empty, reminder, standby, Ac power disconnection, standby
Safety Requirement
- AC power : 100-240V (50/60Hz)
- Battery type - Lithium
- Battery operation time - Standard: 6 hours@5ml/h; Optional: 12 hours@5ml/h
- Charging time - <5hours
- Classification -CF, Class I
- IP Grade - IP24
- Temperature : 0~40°C for operating, -40~70°C for storage
- Humidity : 15~95% for operating, 10~95% for storage
- Air pressure : 57~106kPa for operating, 50~106kPa for storage
Interface
- Data interface - Supported, RS232
- Wireless - Wifi (optional)
- Nurse call - Supported
- DC input - Supported
- Ambulance - Supported, meet EN-1789 requirement
Brand: MINDRAY
Packing: 1 UNIT